A power transmission line feeds input power at 2.3 kV to a step down transformer with its primary winding having 3000 turns. The output power is delivered at 230 V by the transformer. The current in the primary of the transformer is 5 A and its efficiency is 90\%. The winding of transformer is made of copper. The output current of transformer is A.
Answer
45
Solution
Pin=VpIp=2300 5 W
= PoutPin: VsIs=0.9 2300 5
Is= 0.9 2300 5230=45 A
Answer: 45